The Jandy Pro Series TruClear is a chlorine generating system designed for efficient pool sanitation. ETL listed, it ensures safe and consistent chlorine production for pools with spas, offering low maintenance and reliable performance.
1.1 Overview and Benefits
The Jandy Pro Series TruClear is a chlorine-generating system designed for pool sanitation, offering efficient and consistent chlorine production. It is ETL listed and certified to UL STD 1081, ensuring safety and reliability. This system is ideal for pools with built-in spas, providing low maintenance and efficient operation. The TruClear system reduces the need for manual chlorine handling, promoting a safer and more convenient pool care experience. Its advanced design minimizes corrosion and scaling, ensuring optimal performance over time. With quiet operation and a compact design, it seamlessly integrates into pool systems. The TruClear system is a cost-effective solution for pool owners seeking a reliable and efficient way to maintain clean, safe water. It is compatible with various pool configurations, making it a versatile choice for residential and commercial use;
Safety Instructions
The Jandy Pro Series TruClear is designed for pools with built-in spas. Disconnect power before servicing. Use copper conductors only. Follow all safety guidelines for safe operation.
2.1 Important Precautions
When working with the Jandy Pro Series TruClear, ensure all safety guidelines are followed. Disconnect power before servicing or opening the service cover. Use copper conductors only, as specified in the manual. Avoid using Ethylene Glycol (anti-freeze) in the system. The TruClear is designed for swimming pools with built-in spas and should not be used in stand-alone spas. Always read and follow the instructions carefully to ensure safe and proper operation. Failure to comply with these precautions may result in system damage or safety hazards. Refer to the manual for detailed instructions and specific safety recommendations. Proper installation and maintenance are essential for optimal performance and safety.
2.2 Compliance with Standards
The Jandy Pro Series TruClear is certified to meet rigorous industry standards, ensuring reliability and safety. It is ETL listed, conforming to UL STD 1081, and certified to CAN/CSA C22.2 No; 218.1. These certifications guarantee that the system meets the necessary safety and performance requirements for chlorine generators in swimming pools and spas. Compliance with these standards ensures the product is designed for safe and efficient operation, adhering to both U.S. and Canadian safety regulations. Always verify that the installation complies with local electrical codes and standards to maintain certification validity. Proper installation and use ensure the system operates within specified safety parameters, providing peace of mind for pool owners and operators. Regular maintenance is crucial to uphold compliance and performance standards.
Installation and Operation
The Jandy Pro Series TruClear requires proper installation by a professional to ensure safe and efficient operation. Always disconnect power before servicing or maintaining the system.
3.1 Installation Steps
The installation of the Jandy Pro Series TruClear requires careful planning and adherence to safety guidelines. Begin by disconnecting all power sources to ensure a safe working environment. Mount the system in a location that avoids direct sunlight and provides easy access for maintenance. Connect the plumbing components according to the manual’s specifications, ensuring proper alignment and sealing to prevent leaks. Next, install the electrical connections using copper conductors only, as specified in the manual. Once all components are securely connected, perform a system test to verify proper operation. Finally, ensure the system is grounded and all safety features are functional before restoring power. Always follow the manufacturer’s instructions for a successful installation.
3.2 Initial Setup and Configuration
After installation, configure the Jandy Pro Series TruClear according to the manual. Start by setting the chlorine output level based on pool size and usage. Ensure the system is properly connected to the pool’s filtration system. Initialize the control panel by following the on-screen instructions, setting the desired sanitization levels. Calibrate the saltwater sensor to ensure accurate readings. Perform a system test to verify proper operation, checking for leaks and ensuring all components function as intended. Review and adjust settings as needed for optimal performance. Always refer to the manual for specific calibration procedures to ensure the system operates efficiently and safely.
3.3 Daily Operation Guidelines
Daily operation of the Jandy Pro Series TruClear involves monitoring chlorine levels, ensuring proper system function, and maintaining clean conditions. Begin by checking the control panel to confirm the system is operational and displaying correct settings. Verify that the chlorine output matches the pool’s needs, adjusting as necessary. Ensure the water flow rate is adequate and free of restrictions. Regularly inspect the electrolytic cell for scale buildup and clean it if needed. Always maintain the recommended salt level in the pool water. Avoid using metal objects near the system to prevent damage. Refer to the manual for specific guidelines on daily checks and adjustments to ensure optimal performance. Proper upkeep ensures efficient and safe chlorine generation for clean pool water.
Maintenance and Troubleshooting
Regularly clean the electrolytic cell to prevent scale buildup and ensure optimal performance. Check for loose connections and inspect the system for leaks. Monitor chlorine levels and adjust settings as needed. Refer to the troubleshooting guide in the manual for diagnosing common issues like low chlorine output or error codes. Winterize the system properly to avoid damage during freezing temperatures. Always follow the manufacturer’s recommendations for maintenance to extend the lifespan of the TruClear system and ensure safe operation.
4.1 Winterizing the System
Winterizing the Jandy Pro Series TruClear system is essential to prevent damage from freezing temperatures. Begin by draining the system and disconnecting power. Use a union wrench to remove the cell from the filter and clean it thoroughly to eliminate scale buildup. Apply a descaling solution if necessary. Inspect and clean the electrolytic plates, then rinse with fresh water. Store the cell in a dry, protected area. Disconnect all hoses and pipes, and insulate exposed components to prevent freezing. Do not use ethylene glycol (antifreeze) in the system. Follow the manufacturer’s guidelines for proper winterization to ensure the system remains functional and ready for use when the pool season resumes.
4.2 Diagnosing and Solving Common Issues
Common issues with the Jandy Pro Series TruClear can often be resolved with basic troubleshooting. Low chlorine production may indicate improper salt levels or a faulty cell. Check the salt level and ensure it is within the recommended range (2700-3900 ppm). If the cell is dirty or scaled, clean it with a descaling solution. Error codes on the control panel can be referenced in the manual for specific solutions. Flow issues may result from clogged filters or improper installation. Ensure all connections are secure and filters are clean. If problems persist, consult the troubleshooting section in the manual or contact a professional. Regular maintenance and proper operation will help minimize issues and extend the system’s lifespan.
Additional Resources
Visit Jandy’s official website for the full manual, quick start guide, and troubleshooting tips. Contact support at 1.800.822.7933 for further assistance.
5.1 Quick Start Guide Overview
The Quick Start Guide for the Jandy Pro Series TruClear provides a concise overview for initial setup and operation. It includes step-by-step instructions for installation, configuration, and basic functionality. Designed for quick reference, the guide covers essential features like chlorine generation settings and system maintenance. Users can download the guide from the official Jandy website or access it through the Fluidra customer support portal. The guide is ideal for new users to familiarize themselves with the system’s core operations and troubleshooting basics. Refer to Document ID H0613400 for the latest version of the Quick Start Guide, ensuring you have the most up-to-date information for smooth system operation.
5.2 Accessing the Full Manual
The full manual for the Jandy Pro Series TruClear can be downloaded from the official Fluidra website or through the product support portal. Document ID H0613500 provides the complete Installation and Operation Manual, which includes detailed instructions for installation, configuration, and maintenance. The manual is available in PDF format, with a file size of 13.14 MB, ensuring comprehensive coverage of all system aspects. Users can visit the Fluidra customer support website or contact their customer service team for assistance. Additionally, the manual can be accessed via the product’s dedicated webpage, offering a direct link for easy download. This resource is essential for understanding advanced features, troubleshooting, and ensuring optimal system performance.